Filter Spec Calculator

Material settled? Now size it. Enter flow rate, operating pressure and filter rating and the tool back-calculates the filter area required, then returns plate count and plate thickness or cartridge count, OD, length and wall thickness - plus actual clean pressure drop, plugging pressure drop and weight. Pressure ratings carry a 2.5x safety factor. Same engine as the pressure re-check tool, so the numbers agree.

✔ Plate / cartridge forms✔ 10 materials✔ Piece count · thickness · ΔP · weight✔ Free human re-check

① Enter the known duty

Filter media form
Product form
Enter gas flow in Nm³/h
System operating pressure, MPa
°C
mm
mm
If the filter has a support grid, enter the grid pitch (commonly 80-150 mm); enter 0 for no support - the span is then taken plate-edge to plate-edge and the result becomes very conservative
kPa - the resistance ceiling acceptable in clean condition (gas typically 3-10, liquid 5-20)
Results are theoretical minimums · in practice rounded up to standard sizes with margin; final per our written selection sheet

② Results

Fill in the form on the left and press "Calculate spec" - here you get:
· How much filter area is needed
· Plate count / cartridge count
· Recommended plate / wall thickness (with structural check)
· Actual clean ΔP and plugging ΔP
· Weight per piece and total
All computed locally in your browser - nothing uploaded, nothing stored.
Specs in hand → next, re-check pressure & flow →

How the calculation works - fully public

The tool is no black box: four steps, and every formula can be taken away and verified:

Step 1 · Set thickness from operating pressure
Plate: P_b = 48·σ_eff·t²/span² (thin plate simply supported on four edges, σ_eff = σ_b × 0.18 × temperature correction), requiring P_b ≥ operating pressure × 2.5
Cartridge: hoop stress P = 2·σ_eff·t/D versus external-pressure buckling P_cr = 2E/(1−ν²)·(t/D)³, take the lower of the two
Thickness is rounded up to the standard plate / wall thickness series - no non-standard values.
Step 2 · Back-calculate flux per unit area from the allowable ΔP
Gas: v = ΔP·k / (μ_air·t) (μ_air = 1.81×10⁻⁵ Pa·s)
Liquid: f = ΔP·k / (μ_water·t) (μ_water = 1.0×10⁻³ Pa·s)
Permeability k = 3.0×10⁻¹³ × (rating/20)^1.85 m². Finer rating means smaller k and lower flux.
Step 3 · Apply industry flux caps and take the stricter value
Gas velocity cap 3 m/min, liquid flux cap 10 m³/(m²·h). If the ΔP-derived flux exceeds the cap, the area is sized at the cap - otherwise ΔP climbs too fast, cleaning gets too frequent and the unit will not survive on the floor.
Step 4 · Area ÷ area per piece = piece count
Plates are counted on both faces (effective area per plate = length × width × 2); cartridges are counted on the cylindrical side wall (πDL). Piece counts round up, then actual clean ΔP and the plugging line (clean × 3) are back-calculated from the real area.

Common size reference

Below are the sizes and thickness ranges we build most often - fill them in directly. Special sizes are possible too; contact us to evaluate.

FormCommon sizesThickness / wall rangeTypical ratingFilter area per piece
Round discs⌀30 - ⌀300 mm1 - 5 mm1 - 100 μm0.0014 - 0.14 m² (both faces)
Square plates100×100 - 1000×1000 mm1.5 - 10 mm2 - 100 μm0.02 - 2.0 m² (both faces)
Raw-edge large platesup to 1200×1200 mm2 - 12 mm5 - 100 μm2.88 m² (both faces)
Cartridges / tubes⌀20 - ⌀160 mm, length 100 - 1500 mm0.5 - 5 mm0.5 - 100 μm0.006 - 0.75 m² (single face)
Through tubes (no end cap)same as above0.5 - 5 mm0.5 - 100 μmSame, excluding end-face area

FAQ

Q1: Why not simply compute area as flow ÷ empirical filtration velocity, and skip the ΔP back-calculation?
Because filtration velocity is not a constant: for the same plate, a finer rating and a thicker plate mean lower flux at the same ΔP. The correct order is to set thickness from operating pressure first, then back-calculate the real flux from allowable ΔP, thickness and permeability, and only then arrive at the area. Using an empirical velocity directly usually undersizes the area, and the pressure drop overshoots the moment the unit goes online.
Q2: Why is the support grid span so critical - and what happens if I get it wrong?
A sintered plate is a thin-plate structure whose pressure capacity scales inversely with the square of the span. An unsupported 500×500 plate measured across its 500 mm edges needs about 20 mm of thickness at 0.4 MPa; with grid support at a 120 mm pitch inside the real filter, 2 mm is enough. Enter 0 and you get a very conservative result; enter the actual grid pitch to get close to reality. If unsure, contact us to confirm the filter internals.
Q3: Can I order directly from the calculated piece count?
It is a theoretical minimum; only after rounding up to standard sizes and adding margin is it orderable. Installation space, sealing faces, cleaning method and the spares ratio also need attention. Send the result page specs to our engineers for a free review and we issue a written selection sheet - no charge.
Q4: Why is gas flow entered in Nm³/h? How do I convert actual-condition flow?
Nm³/h is standard-condition volumetric flow, which makes duties comparable. If you have actual flow (m³/h) at actual temperature and pressure, convert with Qstd = Qact × (Pact/0.1013) × (273/(273+T)). Getting the order of magnitude wrong shifts the required area by several times.
Q5: The calculated ΔP does not match the differential pressure gauge on site. Why?
Three common causes: 1) the medium is more viscous than water/air (oil, slurry) - the actual ΔP is higher and needs a viscosity correction; 2) high solids content pushes the element into the plugging stage quickly; 3) parallel flow, bypass or a cake layer in the real installation changes the effective area. Send us the site duty and we re-check against the actual medium.
Q6: Plate or cartridge for the same flow - which should I pick?
Look at space and cleaning: plate assemblies are compact with large single-piece area, suited to high flow at coarse ratings; cartridges are easy to remove and install, suit duties that need frequent backwashing or replacement, and scale up easily in parallel. At equal area a cartridge has more sealing points, so for very high pressure prefer plates.
Q7: The calculated thickness is very thin (say 1 mm) - can you even make that?
Yes; 1 mm is our standard thinnest step. But thin plates resist deformation weakly and can warp under uneven clamping force, so the sealing face needs extra care. If the pressure is modest but durability matters, spec one thickness step up for little extra cost.
Q8: Does this tool record the data I enter?
No. All calculation runs locally in your browser - no network calls, nothing uploaded, nothing stored. Only when you request a human re-check does the duty reach our engineers, via email.