Enter the specs you already have and re-check whether the pressure rating holds up, whether the face velocity crosses the red line, and where to set the blinding / change-out ΔP. This is step three of our three-step selection: step one the Material Selector, step two the Filter Spec Calculator - once sizes are out, verify them here: the structural review checks pressure capacity, the flow review checks throughput. (Engineering estimates - for formal design, defer to measured test reports.)
Fields marked * are required. Enter dimensions in millimetres (mm) - the actual sizes on your drawing. Plates and cartridges are calculated separately; switch with the tabs above.
—
Baseline: 316L, 20 μm, room temperature, 200×200 mm rectangular. You can see that for the same material, bigger plates hold less pressure and thicker plates hold more.
| Plate thickness | Size 100×100MPa | Size 200×200MPa | Size 300×300MPa | Size 500×500MPa | Burst pressure (200×200)MPa | Air ΔP (20 μm)kPa | Air ΔP (5 μm)kPa |
|---|
How the material changes pressure capacity at equal thickness and size (200×200 mm, 3 mm thick).
| Material | Tensile strengthMPa | Max service temp°C | Densityg/cm³ | 3 mm ratingMPa | 5 mm ratingMPa | Notes |
|---|
Most often the ΔP or the medium is mismatched: the vendor quotes at 0.05 MPa while you compute at 0.02 MPa - a gap of 40% or more is perfectly normal; or the vendor's data is for clean water while your medium is a slurry with 5× the viscosity. Before comparing numbers, align three things first: medium, ΔP, temperature. If all three match and it is still off by a factor of two, ask the other side for a measured flux report.
Flux scales roughly with the 1.3-1.5th power of pore size: halve the pore and flux falls to 1/2.5-1/3. That is physics, not a product defect. Read it in reverse and it becomes an opportunity: loosening the rating one step is the single most effective way to save filter area - confirm how fine the downstream really needs to be before talking about area.
Mesh has 2-D straight-through channels, so flux is typically 2-4× higher, but it works by surface straining: low dirt-holding capacity, it dies fast once blinded, and the rating drifts after backwash. Powder sintering is a 3-D depth structure: lower flux, but high dirt-holding capacity, repeatedly regenerable, stable rating. Choose mesh for flux; choose powder for stability and life - the two do not substitute for each other.
For liquids, heating cuts viscosity and flux rises - take water from 20 °C to 80 °C and viscosity falls to about 1/2.8 while flux gains roughly 2.8×. That is why for many viscous duties, adding a heater is an order of magnitude cheaper than adding 60 cartridges. One caveat: near the boiling point the pump cavitates easily, so check the available NPSH.
Plates scale with the square: from 2 mm to 4 mm thick, capacity rises about 4×. For cartridges it depends on who governs: roughly linear when stress-controlled, but cubic when buckling-controlled - an even bigger jump. The wall-thickness comparison table in the structural review above exists exactly for this: watch row by row where each entry flips from "buckling" to "stress-controlled".
Fix the structure before the material: thicken it, shorten the span, add a support skeleton - usually far cheaper than upgrading the material. Swaps like 310S → 316L or 316L → C276 solve a corrosion problem, not a capacity shortfall - a strong grade like C276 does carry roughly 30% more, but a gap of more than 2× cannot be closed by material alone.
Flange-clamped or welded plates really do hold 2-3× more than a free plate, but boundary conditions cannot be standardized - write them into the calculation and you might overestimate, and overestimating means unsafe. This tool always uses the worst case (free plate with simply supported edges): if the calculation says it is enough, the installed plate is definitely enough; where the calculation says not enough, add supports and confirm by measurement.
Three cases: ① pressure equipment, or scenarios requiring written commitments (hydrostatic / burst test mandatory); ② high-solids, scaling-prone slurries (flux can only come from pilot testing); ③ cyclic loads and shock duty (fatigue - beyond what calculation covers). The value of the online re-check is screening out clearly unworkable specs before prototyping - saving money and time.
Send the medium, dimensions and duty - we re-check your spec free, in writing · Measurement data available with every shipment · Free sample comparison