ALION FILTER
Home / Tools / Filter spec reviewer

Filter Spec Reviewer (Pressure + Flow)

Enter the specs you already have and re-check whether the pressure rating holds up, whether the face velocity crosses the red line, and where to set the blinding / change-out ΔP. This is step three of our three-step selection: step one the Material Selector, step two the Filter Spec Calculator - once sizes are out, verify them here: the structural review checks pressure capacity, the flow review checks throughput. (Engineering estimates - for formal design, defer to measured test reports.)

✔ Two reviews, one page✔ Conservative free-plate basis✔ Layers × span tables✔ Free human re-check
Structural review (pressure / burst)
"Once this spec is installed, will it be crushed?"
  • Enter the fixed dimensions: L × W / diameter, wall thickness, material, rating, temperature
  • Bigger plate, lower pressure rating (inverse-square law) - large-area plates must be paired with a support skeleton
  • Computed conservatively as a free plate (simply supported on four edges) - the result is never overestimated
  • Output in MPa | failure modes: deformation, cracking, burst - irreversible
Flow review (capacity / running ΔP)
"Can this spec pass my flow?"
  • Enter the fixed area: unit size, piece count, rating, medium, temperature, ΔP
  • Finer rating, higher ΔP - 0.5 μm can cost a hundred times the resistance of 50 μm
  • Computes the clean initial ΔP and the actual capacity, compared against your demand
  • Output in kPa / m³·h | once ΔP climbs to the blinding line, backwash or replace
In one sentence: the structural review asks "will it be crushed?", the flow review asks "can it pass the flow, and when does it blind?" Pressure is the safety floor and flow is the capacity promise - a spec counts as final only when both checks pass.
⚠️ The most common misuse: "My equipment runs at 1.0 MPa system pressure - is the plate's pressure rating enough?" - the question itself is flawed. System gauge pressure ≠ the net ΔP across the plate. If pressure rises and falls in step on both sides of the plate (the whole line pressurized together), the net ΔP the plate actually sees may be only a few dozen kPa. What loads the structure is always the net ΔP across the two sides.
🧭 Where this sits among the three steps: Material not decided yet? Start with the Material Selector; size not calculated yet? Use the Filter Spec Calculator; spec already in hand? Re-check it on this page - finish all three steps and the selection loop is closed.
🛡 Structural review (pressure) 💧 Flow review (capacity / ΔP)
① Pick the type and fill in the parameters

Fields marked * are required. Enter dimensions in millimetres (mm) - the actual sizes on your drawing. Plates and cartridges are calculated separately; switch with the tabs above.

Filter media form
Powder-sintered Sintered wire mesh
Product form
▭ Plate parameters ⌷ Cartridge (tubular) parameters
▭ Rectangular plate ◯ Round plate
× mm
② Results

—

Pressure rating (design working net ΔP)
—MPa
Includes 2.5× safety factor · recommended value
Theoretical burst pressure
—MPa
Simply supported on four edges · conservative
Working ΔP (air · clean)
—kPa
—
Working ΔP (water · clean)
—kPa
—
Effective span used in calculation
—
Suggested backwash / change-out ΔP
—
Max service temperature of this material
—
Plate areal density (reference)
—
Material notes
—
③ Common spec quick table (click a row to load it above)

Baseline: 316L, 20 μm, room temperature, 200×200 mm rectangular. You can see that for the same material, bigger plates hold less pressure and thicker plates hold more.

Plate thickness Size 100×100MPa Size 200×200MPa Size 300×300MPa Size 500×500MPa Burst pressure (200×200)MPa Air ΔP (20 μm)kPa Air ΔP (5 μm)kPa
④ Material comparison

How the material changes pressure capacity at equal thickness and size (200×200 mm, 3 mm thick).

MaterialTensile strengthMPaMax service temp°C Densityg/cm³3 mm ratingMPa 5 mm ratingMPaNotes
⑤ Calculation basis & disclaimer
Calculation basis (engineering estimates, not factory test values)
  • Pressure capacity: large-deflection thin-plate theory Pb = K · σ_eff · (t/a)², with K = 48 for four-edge simple support (conservative); σ_eff = dense-material tensile strength × sintered reduction 0.18 × temperature reduction. Rectangles use the short side as the effective span; rounds use the diameter.
  • Working ΔP: Darcy's law ΔP = μ·v·t / k, with permeability calibrated at 20 μm / 35% porosity and scaled with the 1.85th power of pore size. What is computed is the clean initial ΔP.
  • Cartridge pressure capacity: thin-wall hoop stress P = 2·σ_eff·t / D (switching to the thick-wall Lamé formula when t/D ≥ 0.1), plus an external-pressure buckling check P_cr ≈ 2E/(1−ν²)·(t/D)³ (E = 180 GPa, conservative long-cylinder value). The lower of the two is the structural limit, then divided by the 2.5× safety factor. With thin walls, stability - not strength - usually fails first.
  • Cartridge ΔP: the same Darcy formula as for plates, with the wall thickness taken as the filter-layer thickness; filter area = outer surface πDL, plus the bottom area πD²/4 when one end is closed and the bottom is perforated; a solid bottom is not counted. Blinding ΔP is set at 3× the initial ΔP as the backwash / change-out trigger line.
  • Why a free plate: this is the "worst case". In a real assembly with flange clamping or a support skeleton, capacity will be higher; computing as a free plate guarantees the result is never overestimated - safe.
⚠️ Disclaimer (important)
  • This tool is an engineering estimate for selection communication and quick judgment; it cannot replace factory test reports or pressure-vessel design calculations.
  • Capacity scales inversely with the square of size: going from a 200 mm side to 400 mm leaves only 1/4 of the capacity. Large-area plates must be paired with a support skeleton.
  • Mesh parts: every ΔP given here is an empirical range for judging "usable, roughly how much" - do not use them directly as design inputs or acceptance criteria. Formal supply follows our drawings and measured prototype data.
  • Real capacity depends heavily on the boundary conditions: welded > flange-clamped > edges free - a difference of 2-3× is possible.
  • Medium corrosion, cyclic loads, shock loads and installation stress all significantly reduce actual pressure capacity.
  • For pressure equipment, or any scenario requiring written commitments or tenders, physical hydrostatic / burst testing is mandatory.
⑥ FAQ (applies to both reviews)

The result differs from the vendor's figure by a factor of two - who is wrong?

Most often the ΔP or the medium is mismatched: the vendor quotes at 0.05 MPa while you compute at 0.02 MPa - a gap of 40% or more is perfectly normal; or the vendor's data is for clean water while your medium is a slurry with 5× the viscosity. Before comparing numbers, align three things first: medium, ΔP, temperature. If all three match and it is still off by a factor of two, ask the other side for a measured flux report.

Why does capacity drop so much going from 10 μm to 5 μm?

Flux scales roughly with the 1.3-1.5th power of pore size: halve the pore and flux falls to 1/2.5-1/3. That is physics, not a product defect. Read it in reverse and it becomes an opportunity: loosening the rating one step is the single most effective way to save filter area - confirm how fine the downstream really needs to be before talking about area.

Mesh vs powder at the same rating - how big is the capacity gap?

Mesh has 2-D straight-through channels, so flux is typically 2-4× higher, but it works by surface straining: low dirt-holding capacity, it dies fast once blinded, and the rating drifts after backwash. Powder sintering is a 3-D depth structure: lower flux, but high dirt-holding capacity, repeatedly regenerable, stable rating. Choose mesh for flux; choose powder for stability and life - the two do not substitute for each other.

Why does capacity go UP when the temperature rises?

For liquids, heating cuts viscosity and flux rises - take water from 20 °C to 80 °C and viscosity falls to about 1/2.8 while flux gains roughly 2.8×. That is why for many viscous duties, adding a heater is an order of magnitude cheaper than adding 60 cartridges. One caveat: near the boiling point the pump cavitates easily, so check the available NPSH.

How much pressure capacity does one step of extra wall thickness buy?

Plates scale with the square: from 2 mm to 4 mm thick, capacity rises about 4×. For cartridges it depends on who governs: roughly linear when stress-controlled, but cubic when buckling-controlled - an even bigger jump. The wall-thickness comparison table in the structural review above exists exactly for this: watch row by row where each entry flips from "buckling" to "stress-controlled".

The re-check fails - resize first or change material first?

Fix the structure before the material: thicken it, shorten the span, add a support skeleton - usually far cheaper than upgrading the material. Swaps like 310S → 316L or 316L → C276 solve a corrosion problem, not a capacity shortfall - a strong grade like C276 does carry roughly 30% more, but a gap of more than 2× cannot be closed by material alone.

Why compute as a "free plate"? My plate is flange-clamped.

Flange-clamped or welded plates really do hold 2-3× more than a free plate, but boundary conditions cannot be standardized - write them into the calculation and you might overestimate, and overestimating means unsafe. This tool always uses the worst case (free plate with simply supported edges): if the calculation says it is enough, the installed plate is definitely enough; where the calculation says not enough, add supports and confirm by measurement.

When is physical testing mandatory rather than calculation alone?

Three cases: ① pressure equipment, or scenarios requiring written commitments (hydrostatic / burst test mandatory); ② high-solids, scaling-prone slurries (flux can only come from pilot testing); ③ cyclic loads and shock duty (fatigue - beyond what calculation covers). The value of the online re-check is screening out clearly unworkable specs before prototyping - saving money and time.

← Step 1: pick the material ← Step 2: size the spec

Questions about your parameters? Email our engineers

Send the medium, dimensions and duty - we re-check your spec free, in writing · Measurement data available with every shipment · Free sample comparison

Email [email protected]