Answer 4 questions and match your duty to the right grade in 30 seconds - from 304 / 316L / 430 / 310S / titanium Gr.1-Gr.2 / Hastelloy C276 / C22 / Monel 400 / Inconel 600 / 625. The logic mirrors what our engineers do by hand; results are a first-pass reference. Send us the duty and we re-check it free, in writing.

✔ 10 grades covered✔ 30-second result✔ Free human re-check✔ Plates & cartridges

① Your duty

1 Working temperature
80 °C
2 Medium corrosivity
3 Chloride concentration
4 Filter medium
5 Product form
Indicative only · free written re-check by our engineers on request

Three things to know first

1 · Chloride is killer No.1
Stainless only fears chloride: above 2,000 ppm, or chloride-bearing above 60 °C, pitting and stress-corrosion crack through in months. Only titanium holds that duty safely.
2 · High temperature ≠ corrosion resistance
310S takes 900 °C but has zero chloride-pitting resistance; titanium resists chloride but not hydrochloric acid. Never use a heat grade to fight corrosion.
3 · Alloy premium is cheaper than downtime
316L costs 15-30% more than 304. If the medium is even slightly uncertain, go 316L - one cartridge change plus lost production buys several batches.
Duty hard to describe? Email our engineers:
[email protected]
Send medium, concentration and temperature - we reply with a judgment, not a brochure.
Material settled → size it next → Already sized → re-check pressure & flow →

10-grade quick reference

This table is the knowledge base behind the tool. While you use the selector, the matching row lights up.

GradeUNSMax service tempStrengthLimitsTypical duty
304S30400≤300 °CLowest cost, general neutral / mild dutyChloride must stay <200 ppm; not for high tempWater treatment, general gas filtration, coarse food filtration
316LS31603≤400 °C (≤60 °C with chlorides)Best overall value; food & pharma gradePitting / SCC risk above 2,000 ppm chloridePharma, food & beverage, chemical intermediates, steam
310SS31008≤900 °CHigh-temp oxidation & carburization resistanceNo chloride-pitting resistanceHeat-treatment furnace atmospheres, hot flue gas
430S43000≤600 °CNickel-free, for mild dutyWeaker than 304; finished parts cost more (niche, made to order)Atmospheric gas, mildly corrosive liquids - no stock, custom runs only
Titanium Gr.1 / Gr.2 (TA1 / TA2)R50250 / R50400≤300 °CNearly immune to chloride; best for seawater / wet chlorineNo resistance to reducing acids, fluorides, hot dry chlorineDesalination, chlor-alkali, sodium hypochlorite, wet chlorine gas
Hastelloy C276N10276≤650 °CHandles oxidizing + reducing media; strongest pitting resistancePricy; must weld with C276 fillerMixed acids, HCl + H₂SO₄, chloride-bearing organics
Hastelloy C22N06022≤450 °CMixed-acid all-rounder, better pitting & weld-zone behavior than C276Rare grade, often delivers dearer than C276; lower temp ceilingOxidizing + reducing mixed acid, FGD, hydrometallurgy
Monel 400N04400≤480-550 °CPurpose-built for seawater and HFNot for strong oxidizing acids (nitric)Hydrofluoric acid, seawater, brine, alkaline media
Inconel 600N06600≤1,100 °CUltra-high-temp strength and oxidation resistanceNot its game in pure acid immersionHot flue gas below 1,100 °C, cracking service, heat treatment
Inconel 625N06626≤980 °CHigh temp + strong corrosion in one gradeHard to machine, long lead timeHot chloride duty, FGD, offshore engineering

Temperature ceilings are continuous-service guidance; short peaks may run higher. Final judgment always weighs the full duty.

The rules are fully public

No black box - this is the selection sequence our engineers run every day. Follow it yourself if you like:

  1. Medium is hydrofluoric acid → Monel 400 (nickel-copper alloy built for HF)
  2. Medium is reducing acid (HCl, H₂SO₄) or mixed acid → Hastelloy C276 (the only grade that eats both)
  3. Medium is oxidizing acid: above 300 °C → Inconel 600; at or below → titanium Gr.1
  4. Temperature above 900 °C → Inconel 600; above 650 °C → 310S
  5. Chloride duty: above 2,000 ppm / seawater, or chloride-bearing above 60 °C → titanium Gr.1/Gr.2; otherwise 316L
  6. Mild duty: chloride below 200 ppm and ≤300 °C → 304 (save the money); everything else → 316L
  7. Fallback: above 400 °C → 310S; else 316L
The two classic mis-picks, called out in advance:
1 · Putting 310S / Inconel 600 on chloride duty - heat resistance is not chloride resistance; hot chloride pits far faster than cold. Go titanium.
2 · Putting titanium on hydrochloric / dilute sulfuric acid - titanium has almost no defense against reducing acids. Go C276.

FAQ

Q1: How accurate is the result? Can I order straight from it?
Good enough for a first pass: the rules match our engineers' manual process, and the temperature / corrosion limits come from our material master table and test data. A formal selection still weighs rating, pressure drop, life and cost, so the result page includes a free human re-check - send us the duty and we answer in writing, no charge.
Q2: The medium is a mixture and I can't characterize it. Now what?
Pick "mixed acid / not sure" and the tool falls back to the most conservative pick, C276. Simpler still: email us the medium name, concentration and temperature and we'll judge it directly.
Q3: Why titanium for hot chloride duty instead of 316L?
Chloride is killer No.1 for austenitic stainless: above 2,000 ppm or 60 °C, 316L's pitting and stress-corrosion risk climbs sharply, and the failure mode - perforation or brittle cracking - typically shows up months after startup. Titanium tolerates tens of thousands of ppm chloride; it is the only safe call at high chloride.
Q4: How big is the 304 vs 316L gap - is the upgrade worth it?
316L powder and sintering cost roughly 15-30% more. With chloride under 200 ppm and temperature at or under 300 °C, 304 is enough. The moment the medium is salty or uncertain, go 316L - one cartridge replacement costs more than the alloy premium.
Q5: The tool picked something different from what I run today. Switch?
Not automatically. First check whether the current material shows corrosion signs (pitting scars, discoloration, strength loss). If not, keep running it and shorten inspection intervals. If signs exist or the duty is about to get harsher (hotter, new medium), switch per the tool's pick. Unsure? Email us the current state and we'll re-check.
Q6: Material settled - how do I fix size and wall thickness?
That's the next tool, the filter spec calculator: feed in flow and working pressure and it returns plate thickness/diameter or cartridge diameter/length/thickness.
Q7: Does plate vs cartridge change the material logic?
No - the recommendation logic is identical. The difference is where it lands: plates map to sintered filter plates / discs, cartridges to sintered tubes. The result links to the matching product page for the form you picked.
Q8: Does the tool upload or store what I enter?
No. Everything runs locally in your browser - no network calls, no storage. Only when you ask for a human re-check does the duty reach our engineers, via email.